Standards
EN 50525-3-41 (Construction and tests)
Low voltage Directive: 2014/35/UE
RoHS compliant
Quality certificate


Technical characteristics & performances
-
Single-core
-
Bunched conductor (class 5) mm2
-
Maximum service temperature: 90ºC / 250ºC
-
450 / 750 V C.A.
-
Easy peeling / easy strip
Fire performance
-
Flame retardant
-
Fire retardant
-
Low opacity & production of smoke
-
Low acidity & conductivity of the gases: pH<4,3 10 µS/mm
-
Halogen free
-
Low emission of toxic gases
Uses and applications
-
Panel and appliance wiring
-
Installations with risk of fire or explosion
-
BD2, BD3, BD4 (skyscrapers, tunnels…)
-
Buildings receiving the public
Packaging
-
Coil
-
Drum
DOWNLOADS:
Technical DatasheetFunctional features
-
Technical designation:
H07Z-K
-
Constructive description:
EN 50525-3-41 (Construction and tests)
Single core non-sheathed cables with halogen-free crosslinked insulation and low emission of smoke
- CONDUCTOR:
Flexible, annealed, plain copper conductor, class 5 acc. to IEC 60228, EN 60228.
- INSULATION:
Halogen free cross-linked polyolefin compound (Type EI 5) acc. to EN 50363-5.
Number of cores: 1
Cross-sectional area size range: 1,5 to 240 mm2. -
Rated voltage:
450/750 V
-
Normal operation temperature:
90ºC
-
Short-circuit temperature (5 s max):
250ºC
-
Voltage test:
2,5 kV
-
Colour:
*INSULATION: black, brown, gray, blue, yellow-green, red, white. Other colours on request.
-
Fire performance:
- Flame retardant: EN 60332-1-2; IEC 60332-1 (H ≤ 425 mm)
- Fire retardant: EN 60332-3-24; IEC 60332-3-24 (H ≤ 2,5 m)
- Low opacity of emitted smokes: UNE EN 61034-2; IEC 61034-2
60% < Light transmittance
In case of fire, it avoids loss of visibility due to smoke produced by cable combustion
- Low acidity and conductivity of the emitted gases: EN 60754-2; IEC 60754-2
pH≥4,3 conductivity < 10 microsiemens/mm
- Halogen free. Low emission of toxic gases: EN 60754-1, EN 60684-2, IEC 60754-1, IEC 60684-2 (HCl <0,5 % & Fluor < 0,1 %) -
Type of installation:
Fixed
-
User´s guide:
In locations where a low level of emission of smoke and corrosive gases are required in case of fire or burning. Installation in surface-mounted or embedded conduits, or similar closed systems.
They are recommended for fixed and protected installation in lighting and control gear for voltages upo to and including 1.000 V A.C or up to 750 V D.C. to earth.
(EN 50565-2)
They are suitable for internal wiring in electrical boards and fixed installations. -
Technical instructions:
.
-
Conductor:
Flexible
-
Halogen free:
Yes
-
Armoured cable:
No