Standards
IEC 60502-1, UNE 21123-2
(Construction and tests)
IEC 60332-1-2, IEC 60332-3-24 (Fire performance)
Low Voltage Directive: 2014/35 / EU
RoHS compliant
Quality certificate


Technical characteristics & performances
-
Multicore
-
Bunched conductor (class 5) mm2
-
Maximum service temperature: 90ºC / 250ºC
-
0,6/1 (1,2) kV C.A
-
Tensile forces
-
Mechanical protection
-
Low temperature resistance
-
Anti rodents
Fire performance
-
Flame retardant
-
Fire retardant
Uses and applications
-
Distribution networks
-
Industral use
-
Exterior lighting
-
Outdoor use
Packaging
-
Drum
Functional features
-
Technical designation:
RVMV-K 0,6/1 kV (multicore cables)
-
Constructive description:
IEC 60502-1, UNE 21123-2 (Construction and tests)
- CONDUCTOR:
Flexible, annealed, plain copper conductor, class 5 based on International standard IEC 60228.
- INSULATION:
Cross-linked polyethylene (XLPE) according to International standard IEC 60502-1
- ASSEMBLY OF CONDUCTORS:
In multicore cables, the cores are cabled helically.
- INNER SHEATH:
PVC type ST2 according to International standard IEC 60502-1.
- ARMOUR:
A single layer of galvanized steel wires armour acc. to IEC 60502-1 / UNE 21123-2.
- OUTER SHEATH:
PVC type ST2 according to International standard IEC 60502-1.
Barryflex AR-Corona RVMV-k 0,6/1 kV is only multicore cable (2,3,4,5 cores / From 1,5 up to 150 mm2)
Identification of cores HD 308 S2:
2x - brown and blue
3x - brown, black and gray
3G - brown, blue and yellow / green
4x - brown, black, gray, blue
4G - brown, black, gray, yellow / green
5G - brown, black, gray, blue, yellow / green -
Rated voltage:
0.6/1 kV
-
Normal operation temperature:
90ºC
-
Short-circuit temperature (5 s max):
250ºC
-
Voltage test:
3,5 kV
-
Colour:
Black
-
Fire performance:
- Flame retardant: UNE EN 60332-1-2 ; IEC 60332-1-2 (H≤425 mm)
- Fire retardant: UNE EN 60332-3-24; EN 60332-3-24 (Cat. C). -
Type of installation:
Fixed
-
User´s guide:
It is specially indicated for its use in distribution networks in which there is a high risk of explosion, mechanical aggressions or tensile stress.
For transport and distribution of electrical energy infixed facilities, protected or not.
Suitable for indoor or outdoor uses.
NOTE:
RVhMVh-K: Available with special sheath compound with mineral oils & liquid fuels resistance (acc. to UIC 895 OR) and with reduced halogen emissions (>15% HCl acc. to IEC 60754). Please, contact our Commercial Department for more information. -
Technical instructions:
.
-
Conductor:
Flexible
-
Halogen free:
No
-
Armoured cable:
Yes