Standards
IEC 60502-1, UNE 21123-2
(Construction and tests)
LOW VOLTAGE DIRECTIVE: 2014/35 / EU
CPR Regulation (EU) No 305/2011:
Reaction to fire (Eca)
RoHS compliant
Quality certificate




Technical characteristics & performances
-
Single-core
-
Multicore
-
Bunched conductor (class 5) mm2
-
Maximum service temperature: 90ºC / 250ºC
-
0,6/1 (1,2) kV C.A
-
Low temperature resistance
-
Easy peeling / easy strip
-
Protection against Electromagnetic disturbances
Fire performance
-
Eca (reaction to fire)
-
Flame retardant
Uses and applications
-
Control & command
-
Distribution networks
-
Industral use
-
Exterior lighting
-
Outdoor use
-
Instrumentation
Packaging
-
Drum
Functional features
-
Technical designation:
RC4V-K 0,6/1 kV
-
Constructive description:
IEC 60502-1, UNE 21123-2 (Construction and tests)
- CONDUCTOR:
Flexible, annealed, plain copper conductor, class 5 based on International standard IEC 60228.
- INSULATION:
Cross-linked polyethylene (XLPE) according to International standard IEC 60502-1
- ASSEMBLY OF CONDUCTORS:
In multicore cables, the cores are cabled helically.
- SHIELD:
Al/PET tape + tinned copper braid.
Coverage: 100 %.
- OVERSHEATH:
PVC type ST2 according to International standard IEC 60502-1.
Identification of cores HD 308 S2:
2x - brown and blue
3x - brown, black and gray
3G - brown, blue and yellow / green
4x - brown, black, gray, blue
4G - brown, black, gray, yellow / green
5G - brown, black, gray, blue, yellow / green -
Rated voltage:
0.6/1 kV
-
Normal operation temperature:
90ºC
-
Short-circuit temperature (5 s max):
250ºC
-
Voltage test:
3,5 kV
-
Colour:
Oversheath: Black / Insulation: HD 308 S2
-
Fire performance:
- Reaction to fire: Eca (EN 50575:2014+A1:2016)
• EN 60332-1-2; IEC 60332-1 (H≤425 mm) Flame retardant
For covered range (+ information), please check out "CPR/DoP" section in our website.
*The packaging labels of these cables include the CE marking according to the CPR Regulation ((EU) Nº 305/2011) articles 8 and 9. -
Type of installation:
Fixed
-
User´s guide:
Barryflex SHIELD RC4V-K 0,6/1 kV power, control & command cables are specially indicated for its use in distribution networks, power stations, industries or buildings and electrical installations where a protection against electromagnetic interference is necessary (EMC).
“ (...)For electrical energy transport and distribution, distribution networks, protected or not. For indoor and outdoor installations. Non suitable for facilities of feeding of submerged pumps. (...)” -
Technical instructions:
.
-
Conductor:
Flexible
-
Halogen free:
No
-
Armoured cable:
No