North America Icon North America
Latin America Icon Latin America

Product Catalogue

You are in: Home | Catalogue | Afirenas RZ1FAZ1-K/RZ1FZ1-K
Back to product search

Afirenas RZ1FAZ1-K/RZ1FZ1-K

Standards

IEC 60502-1 (Construcción y ensayos)

IEC 60332-1-2, IEC 60332-24, IEC 60754-1 y 2, IEC 61034-2
(Comportamiento en caso de incendio)

LOW VOLTAGE DIRECTIVE: 2014/35 / EU

RoHS compliant

Quality certificate

Certificate icon Low voltage Directive (LVD): 2014/35/EUCertificate icon RoHS

Technical characteristics & performances

  • Single-core Propiedad del cable: Single-core
  • Multicore Propiedad del cable: Multicore
  • Bunched conductor (class 5) mm2 Propiedad del cable: Bunched conductor (class 5) mm2
  • Maximum service temperature: 90ºC / 250ºC Propiedad del cable: Maximum service temperature: 90ºC / 250ºC
  • 0,6/1 (1,2) kV C.A Propiedad del cable: 0,6/1 (1,2) kV C.A
  • Mechanical protection Propiedad del cable: Mechanical protection
  • Oil resistance Propiedad del cable: Oil resistance
  • Low temperature resistance Propiedad del cable: Low temperature resistance
  • Anti rodents Propiedad del cable: Anti rodents

Fire performance

  • Flame retardant Propiedad del cable: Flame retardant
  • Fire retardant Propiedad del cable: Fire retardant
  • Low opacity & production of smoke Propiedad del cable: Low opacity & production of smoke
  • Low acidity & conductivity of the gases: pH<4,3 10 µS/mm Propiedad del cable: Low acidity & conductivity of the gases: pH<4,3 10 µS/mm
  • Halogen free Propiedad del cable: Halogen free
  • Low emission of toxic gases Propiedad del cable: Low emission of toxic gases

Uses and applications

  • Distribution networks Propiedad del cable: Distribution networks
  • Installations with risk of fire or explosion Propiedad del cable: Installations with risk of fire or explosion
  • BD2, BD3, BD4 (skyscrapers, tunnels…) Propiedad del cable: BD2, BD3, BD4 (skyscrapers, tunnels…)
  • Buildings receiving the public Propiedad del cable: Buildings receiving the public
  • Industral use Propiedad del cable: Industral use
  • Exterior lighting Propiedad del cable: Exterior lighting
  • Outdoor use Propiedad del cable: Outdoor use

Packaging

  • Drum Propiedad del cable: Drum


Functional features

  • Technical designation:
    RZ1FAZ1-K(AS) 0,6/1 kV (single core cables)  / RZ1FZ1-K(AS) 0,6/1 kV (multicore cables)
  • Constructive description:
    IEC 60502-1, UNE 21123-4 (Construction and tests)

    - CONDUCTOR:
    Flexible, annealed, plain copper conductor, class 5 based on standard IEC 60228.
    - INSULATION:
    Cross-linked polyethylene (XLPE) according to International standard IEC 60502-1
    - ASSEMBLY OF CONDUCTORS:
    In multicore cables, the cores are cabled helically.
    - INNER SHEATH:
    Extruded polyolefin type ST8 according to International standard IEC 60502-1.
    - ARMOUR:
    Steel (multicore cables) or aluminium (single-core cables) double tape armour.
    The armour is in accordance with International standard IEC 60502-1.
    - OVERSHEATH:
    Extruded polyolefin type ST8 according to International standard IEC 60502-1.

    Identification of cores HD 308 S2:
    2x - brown and blue
    3x - brown, black and gray
    3G - brown, blue and yellow / green
    4x - brown, black, gray, blue
    4G - brown, black, gray, yellow / green
    5G - brown, black, gray, blue, yellow / green
  • Rated voltage:
    0.6/1 kV
  • Normal operation temperature:
    90ºC
  • Short-circuit temperature (5 s max):
    250ºC
  • Voltage test:
    3,5 kV
  • Colour:
    Green
  • Fire performance:
    Flame retardant: UNE EN 60332-1-2 ; IEC 60332-1-2 (H≤425 mm)
    Fire retardant: UNE EN 60332-3-24 / IEC 60332-3-24 (cat.C) (H ≤ 2,5 m)
    Low opacity of emitted smokes: UNE EN 61034-2; IEC 61034-2
          60% < Light transmittance. In case of fire, it avoids loss of visibility due to smoke produced by cable combustion
    Low acidity and conductivity of the emitted gases: EN 60754-2; IEC 60754-2
          pH≥4,3 conductivity < 10 microsiemens/mm
    Halogen free. Low emission of toxic gases: UNE EN 50267-2-1 / IEC 60754-1 (HCl <0,5 % y Fluor < 0,1 %)
  • Type of installation:
    Fixed
  • User´s guide:
    It is specially indicated for its use in distribution networks, public concurrence places (airports, museums, malls, schools, hospitals, cinemas,...) and in general, whenever an important fire risk exists or where it´s required a low smoke emission and corrosive gases in case of fire.
    Its use is recommended for installations with presence of rodents, and installations in general where the cable is subject to risk of mechanical aggresion.

    Its special fire performance protects public health, fireman works and avoid any possible damage to electronic equipments. 
  • Technical instructions:
    .
  • Conductor:
    Flexible
  • Halogen free:
    Yes
  • Armoured cable:
    Yes

SEARCH